CCZCL - 520 ADHESIVE
- MSDS: CCZCL
- Manufacturer: ARMSTRONG WORLD INDUSTRIES INC
- Product Name: 520 ADHESIVE
- National Stock Number: 8040-01-015-4187
Product Identification
Product ID:520 ADHESIVE
MSDS Date:03/19/1993
FSC:8040
NIIN:01-015-4187
MSDS Number: CCZCL
Responsible Party
LANCASTER, PA 17604
US
Emergency Phone: 800-255-3942
Info Phone: 717-396-2328
Cage: 03938
Contractor
Telephone: 717-396-2328; 717-396-2935
Cage: 03938
Ingredients
ACETONE (SARA 313) (CERCLA)
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 25-35%
OSHA PEL 1000 PPM
ACGIH TLV: 750 PPM; 1000 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 16.5%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HEXANE (CERCLA)
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: 34%
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
1,3-BUTADIENE, 2-CHLORO-, POLYMERS; (SYNTHETIC RUBBER)
CAS: 9010-98-4
RTECS: EI9640000
Fraction By Weight: 13%
OSHA PEL N/K
ACGIH TLV: N/K
PHENOLIC RESIN
Fraction By Weight: 9%
OSHA PEL N/K
ACGIH TLV: N/K
RUBBER CURING INGREDIENTS
Fraction By Weight: 3%
OSHA PEL N/K
ACGIH TLV: N/K
MANUFACTURING & PACKAGING OF PRODUCT. DURING
RTECS: 9999999ZZ
ARE RECOMMENDED TO PREVENT CONTACT WITH MATERIAL.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN AND EYES: EXCESSIVE SKIN CONTACT
MAY CAUSE DRYING AND CRACKING OF THE SKIN AND RESULT IN DERMATITIS.
CONTACT WITH EYES WILL CAUSE IRRITATION. INHALATION: IRRITATION OF
RESPIRATORY TRACT, COUGHING , HEADACHE, DIZZINESS, DROWSINESS,
NAUSEA, UNCOORDINATED MOVEMENTS. CHRONIC: TOLUENE APPEARS ON THE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: NAVY LIST OF OCCUPATIONAL CHEMICAL
REPRODUCTIVE HAZARDS. SEEK CONSULTATION FROM APPROPRIATE HEALTH
PROFESSIONAL CONCERNING LATEST HAZARD LIST INFO AND SAFE HANDLING
AND EXPOSURE INFO .
Medical Cond Aggravated by Exposure:ANY CONDITION GENERALLY AGGRAVATED
BY SOLVENTS; PREEXISTING UPPER RESPIRATORY AND LUNG DISEASE SUCH
AS, BUT NOT LIMITED TO BRONCHITIS, EMPHYSEMA AND ASTHMA.
First Aid
First Aid:INGEST: CALL MD IMMEDIATELY . SKIN: FLUSH ANY SKIN CONTACT
WITH PLENTY OF WATER. WASH WITH SOAP AND WATER. REFER TO MD IF
IRRITATION OR SYMPTOMS PERSIST. EYES: FLUSH ANY EYE CONTACT WITH
PLENTY OF WATER FOR AT LEAST 15 MINUTES. REFERTO MD IF IRRITATION
OR SYMPTOMS PERSIST. INHAL: REMOVE TO FRESH AIR IF EXPOSED TO
EXCESS CONCENTRATIONS OF VAPOR. SEEK MEDICAL ATTENTION IF SYMPTOMS
PERSIST.
Fire Fighting
Flash Point Method:PMCC
Flash Point:<20F,<-7C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, HALON.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS IN A FIRE MAY RUPTURE
DUE TO PRESSURE BUILDUP; USE WATER TO COOL CONTAINERS TO PREVENT
THIS.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENT AREA OF
SPILL/LEAK; IF USING MECH VENT, MAKE SURE IT IS EXPLO-PROOF OR DOES
NOT PRESENT IGNIT SOURCE. FOR EXPOS ABOVE TLV, WEAR NIOSH APPRVD
RESP EQUIP. CNTN SPILL, P REVENTING IT FROM ENTERING SEWER LINES OR
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN AREA SUITABLE FOR FLAMMABLE
MIXTURES. RECOMMENDED STORAGE TEMPERATURE IS BELOW 90F.
Other Precautions:VAPORS ARE FLAMMABLE & ARE HEAVIER THAN AIR. PROHIBIT
SMOKING AND ELIMINATE ALL OTHER SOURCES OF IGNITION, SUCH AS
REGULAR ELECTRICAL TOOLS AND APPLIANCES MAKING SURE PILOTS ON
GAS-FIRED WATER HEATERS ARE EXTINGUISHED.
Exposure Controls
Respiratory Protection:WITH ADEQUATE VENTILATION, RESPIRATORY EQUIPMENT
SHOULD NOT BE NEEDED. IF ADEQUATE VENTILATION IS NOT AFFORDED, WEAR
NIOSH APPROVED RESPIRATORY EQUIPMENT APPROVED FOR ORGANIC VAPORS.
Ventilation:USE NATRL CROSS-VENT, LOC (MECH) PICK-UP &/OR GEN AREA
(MECH) VENT TO PREVENT ACCUM OF SOLV VAPS, KEEPING IN (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES DURING (ING 7)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: 75 BY WT (30 MIN @ 275F). SPILL PROC: WATERWAYS. USE ABSORB TO
ASSIST W/PICK-UP OF MATL. SCRAPE UP ADHESIVE & PLACE IN CNTNR.
VENT: MIND THAT VENT PATTERN MUST REMOVE HVR/AIR SOLV VAPS FROM L
OWER LEVELS OF WORK SPACES. VENT SHOULDBE SUFFICIENT TO KEEP SOLV
VAP CONC BELOW TLV.
Chemical Properties
Boiling Pt:B.P. Text:>152F,>67C
Spec Gravity:0.83 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:STRAW COLORED LIQUID WITH CHARACTERISTIC SOLVENT
ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE &
OTHER TOXIC VAPS & GASES THAT ARE COMMON TO THERMAL DEGRADATION OF
ORGANIC COMPOUNDS.
Disposal
Waste Disposal Methods:INCINERATION OR OTHER METHOD APPROVED FOR
IGNITABLE WASTES IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.